Pressure Sensor & Switch

Digital Pressure Gauge

RoHS2 Compliant

Easy to check pressure reading with digital display

Advantages

Easy to check pressure reading with digital display

Compact body

Body size:30mm width x 30mm height

Dust & water proof: IP65

IP65 can be maintained by operation with a tube inserted to air release port. (Refer to digital catalog)

A power saving mode is adapted. Battery life is about 3 years.

Only one-time pushing the bottom to indicate pressure value. The battery life is expected when pressure value displayed at 5 times a day basis.

Visible indication of battery change time.

Battery level indicator blinks to notify when battery level becomes low.
With a flat-blade screwdriver (1.4mm width), battery can be replaced.

Various option parts

Specifications

Basic spec.

Fluid medium Air, non-corrosive/non-flammable gas
Battery CR2032 Lithium battery (*2)
Battery life About 3 years (at 5 times indication/day)
Low-power indicator Equipped
Battery replacement Possible
Turn-on interval Display turns off after 60sec.
Sampling rate 2Hz (2 times/sec)
LCD display 7 segment, 3.5 digits
Indicator accuracy ±2% F.S. ±1digit (ambient temperature: 25±3℃)
Protective structure IP65(*1)
Ambient temp. range Operation:0~50℃, Storage:-10~60℃(No dew condensation, no freezing)
Ambient humidity range Operation/Storage:35~85%RH(No dew condensation)
Vibration proof Total amplitude 1.5mm or 100m/s2,10Hz-55Hz-10Hz scan for 1min.,
Direction of X, Y and Z for 2 hours each
Shock resistance 100m/s2,3 times each in direction of X, Y and Z
Temperature characteristic ±2% F.S. of detected pressure (25℃)

* Air tube must be inserted into the atmospheric release port to maintain IP65. (See the below figure. )

Negative pressure type specifications

Rated pressure range -101~0kPa
Indicated pressure range -101~10kPa(*1)
Proof pressure 300kPa
Repeatability ≦±1% F.S. ±1digit

* 0 ~ 10kPa is not guaranteed indicator accuracy for GPD-V-01.

Positive pressure type specifications

Rated pressure range 0.000~1.000MPa
Indicated pressure range -0.100~1.000MPa (*1,*2)
Proof pressure 1.5MPa
Repeatability ≦±0.2% F.S. ±1 digit

*1. The display at the time of applying negative pressure to GPD-01 will be as below figure.

*2. -0.1~0MPa is not guaranteed indicator accuracy for GPD-01.

Port size

Thread size

O.D.:Taper pipe male thread R1/8
I.D.:Metric female thread M5x0.8

Ordering Information

Option & Maintenance items

Digital Pressure Sensor 31& 32 Series with 3-color dual displayWall bracket for 31 Series

Wall bracket
for Digital Pressure Sensor 31 with LCD dual displays with 3-colors.

Digital Pressure Sensor 31& 32 Series with 3-color dual displayUpright bracket for 31 Series

Upright bracket for Digital Pressure Sensor 31 with LCD dual displays with 3-colors.

Digital Pressure Sensor 31& 32 Series with 3-color dual displayPanel adapter set

Panel adaptor set for Digital Pressure Sensor 31 & 32 with LCD dual displays with 3-colors and Indicator for Small Pressure Sensor 11 & 12.

Digital Pressure Sensor 31& 32 Series with 3-color dual displayPanel adapter set with front cover

Panel adapter set with front protective cover for Digital Pressure Sensor 31 & 32 with LCD dual displays with 3-colors and Indicator for Small Pressure Sensor 11 & 12.

Detailed Safety Instructions

Warning

1.Never use with corrosive or flammable gases or liquids.

2.Do not use in an environment with corrosive or explosive gases as it is not explosion-proof.

Caution

1.When handling, do not drop, strike or subject it to strong shocks. Even if it is not damaged in appearance, it may be damaged inside.

2.If there is a risk of water, dust, etc. entering the main unit through the atmospheric release port, connect a tube, etc. to the atmospheric release port and extend the other end to a safe place (where water, etc. will not be splashed). Be careful not to bend the tube or block the end.

3.When using, connect the air filter immediately before the product.

4.The atmospheric release port must always be open to the atmosphere.

5.Use the specified battery. The use of non-specified batteries may cause malfunction.

6.The batteries must be inserted in the correct direction. Incorrect orientation of the battery may cause the battery to explode or leak, resulting in a malfunction or accident. When not in use for a long time, always remove the batteries and store them separately to prevent leakage.

7.This product cannot be calibrated and should not be used for commercial transactions.

Inquiries about this product

It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.

The following are frequently asked questions. Please check before making inquiries.